Personal Dosimeter Pen 200
The advanced PEN direct reading dosimeters are rugged, precision instruments.
The advanced PEN are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose (quantity of gamma and x-ray exposure). PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.
Technical Specification :

Exposure Range (gamma and x-rays)
PEN200mR Scale increments of 10mR
PEN500mR Scale increments of 20mR
PEN2R increments of 100 mR
PEN5R increments of 200mR
PEN20R increments of 1R
PEN2mSv increments of .1mSv
PEN5mSv increments of .2mSv
National Stock Numbers Available

Energy Dependence
±10% maximum change in sensitivity for x and gamma ray energies from 16 keV to 8 MeV.
Electrical Leakage
In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50° C. At 20° C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R, the leakage is less than 5% of full scale in 48 hours at 20° C. Thereafter, the leakage will decrease to original values.
Charging Voltage
Dosimeters are capable of being charged to "zero" with 140 to 195 volts.
Operational Characteristics
A maximum change in sensitivity of ±10% may occur under any probable combination of the following:
A) Temperature range below -20°C (-4°F) or above +50°C (122°F)
B) Greater than 50,000 foot altitude for one month
C) Relative humidity greater than 95% Highly resistant to shock and vibration.
Accuracy
±10% of true dose for Cs-137 or Co-60 gamma.
Rate Response
Dosimeters are dose rate independent.
Enclosure Material
Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic with metal clip.
Weight
Approx. 19 grams (0.7 oz.)
Size
PEN- 200, 500 2mSv, 5mSv Length: 11 cm (4.48 inches) Diameter: 1.5 cm (0.6 inches) PEN- 2, 5, 20 Length: 11.5 cm (4.52 inches) Diameter: 1.5 cm (0.6 inches)
Options
Protective sapphire lens
Warranty
2 year limited warranty